KE7303 portable three phase standard meter is used for the test of three phase / single phase meters, electrical parameter of the power line, the transformer ratio by electric power companies, meter manufacturing companies and institutes of metrology.
Highlight:
- Calibrate the error of all electricity energy meters, checking the constant of the energy meter
- Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter in the same loop
- Measure voltage, current, frequency, power, power factor and phase angle
- Simultaneous measure and display waveforms of three phase voltage and current
- Detect the error change of the clamp automatically; ensure the accuracy stability of the clamp and the instrument in the long run.
- Measure ratio of CT, VA burden of the metering loop from VT and CT secondary terminals.
- Allocate clamp of 20A, 100A, 500A, 1000A to directly measure the comprehensive error
- Measure the 2nd - 51st harmonics of current and voltage
- Display vector diagram, judge the wiring right or wrong automatically
- Read the information of energy meter with barcode scanner (optional)
- Battery, test lead power or external power for choices
- Communicate with PC, download calibration data through USB flash disk, RS-232 or Bluetooth
- Firmware can be upgraded through removed disk by users themselves
- Save and browse the testing data
Main specifications:
|
KE7303-0.05 |
KE7303-0.1 |
Voltage measurement |
Voltage range |
30V - 480V |
Accuracy |
±0.05% |
±0.1% |
Harmonics |
2nd- 51st |
Current measurement |
Current range |
Terminal input |
0.1A - 10A |
Clamp input |
5A,20A,100A,500A,1000A,2000A |
Accuracy |
Terminal input |
±0.05% |
±0.1% |
Clamp input |
±0.2%(5A),±0.5% (others) |
Harmonics |
2nd- 51st |
Power measurement |
Active power |
Terminal input |
±0.05% |
±0.1% |
Clamp input |
±0.2%(5A),±0.5% (others) |
Reactive power |
Terminal input |
±0.05% |
±0.1% |
Clamp input |
±0.2%(5A),±0.5% (others) |
Energy measurement |
Active energy |
Terminal input |
±0.05% |
±0.1% |
Clamp input |
±0.2%(5A),±0.5% (others) |
Reactive power |
Terminal input |
±0.05% |
±0.1% |
Clamp input |
±0.2%(5A),±0.5% (others) |
Phase measurement |
Phase range |
0 - 360° |
Accuracy |
±0.05° |
±0.1° |
Frequency measurement |
Frequency range |
45Hz - 65Hz |
Accuracy |
±0.05Hz |
Pulse output |
High frequency output(CH) |
3.6×107imp / kWh |
Low frequency output(CL) |
3.6×104imp / kWh |
Pulse input |
Input channel |
2 |
Input frequency |
Max. 100Hz |
Others |
Power supply |
Build-in rechargeable battery, external power supply, powered from the tested terminal |
Dimensions |
154mm×249mm×58mm |
Weight |
1.8kg |
Packing
Solid Plastic Case Inside Carton Outside