86-20-62220181
KE7202-0.1 | ||
Voltage measurement | ||
Voltage range | 20V - 265V | |
Accuracy | ±0.1% | |
Harmonics | 2nd - 51st | |
Current Measurement | ||
Current range | Terminal input | 0.1A - 10A |
Clamp CT input | 20A,50A,100A,500A,1000A | |
Accuracy | Terminal input | ±0.1% |
Clamp CT input | ±0.2% (20A), ±0.5% (other) | |
Harmonic | 2nd - 51st | |
Power measurement | ||
Active power | Terminal input | ±0.1% |
Clamp CT input | ±0.2% (20A), ±0.5% (other) | |
Reactive power | Terminal input | ±0.3% |
Clamp CT input | ±0.5% | |
Energy measurement | ||
Active energy | Terminal input | ±0.1% |
Clamp CT input | ±0.2% (20A), ±0.5% (other) | |
Reactive energy | Terminal input | ±0.3% |
Clamp CT input | ±0.5% | |
Phase measurement | ||
Phase angle | 0° -- 360° | |
Resolution | ±0.1° | |
Frequency measurement | ||
Frequency range | 45Hz - 65Hz | |
Resolution | ±0.05Hz | |
Pulse input | ||
Input channel | 1 | |
Input frequency | Max. 100Hz | |
Pulse output | ||
Output channel | i | |
Output constant | 3.6×108 imp / kWh | |
Current output | ||
Output range | 0 - 10A | |
Power capacity | 20VA | |
Miscellaneous | ||
Power supply | External power supply, powered from the tested terminal |
|
Dimensions | 154mm×249mm×58mm | |
Weight | 1.5kg |